    商品詳情

      供應Magee黑碳儀

      深圳市現代豪方儀器儀表科技有限公司——來電請轉 余工

      TCA 08型總碳分析儀

      (TOTAL CARBON ANALYZER MODEL TCA08)

      PRODUCT INFO

      The analytical system of the Magee Scientific Total Carbon Analyzer is constructed entirely from stainless steel, making the instrument rugged, simple and reliable. The analysis uses ambient air as the carrier gas. This eliminates the need for specialty gas supplies, and greatly simplifies the installation, use, and maintenance of the instrument.

      In contrast to existing methods, the TCA offers greater reliability, greater flexibility, and substantial operational cost savings for aerosol analysis.

       

      The TCA08 can be used in online mode for continuous, real-time analysis: and offline mode to analyze previously-collected samples..

       

      ADVANTAGES AND BENEFITS

      CONTINUOUS OPERATION

      The timebase for sampling and analysis is adjustable from 20 minutes to 24 hours.

      NO GAS, NO GLASS

      Ambient air is used as the analytical carrier gas at a very low flow rate. This eliminates the need for specialized gas supplies.

      The analytical chambers are made of stainless steel: the instrument contains no fragile glass components.

      OC/EC DETERMINATION

      The Total Carbon Analyzer provides the result for TC.

      Since {TC = OC + EC}, it follows that {OC = TC EC}.

      The Total Carbon Analyzer may be connected to a Model AE33 Aethalometer, which provides real-time data for BC, closely related to EC. The Aethalometer data is automatically combined with the TCA data to provide a full characterization of the carbonaceous component of the aerosol in near-real-time: TC, OC, BC (or EC).

      CONTINUOUS OPERATION

      One channel collects the sample, while the second parallel channel is being analyzed. Ball valves automatically switch between the two, every timebase period, to provide continuous operation.

      QUICK INSTALLATION, AUTOMATIC OPERATION

      The instrument can be installed quickly with no specialized resources required. It operates automatically and recovers from power interruptions.

       

      OC/EC DETERMINATION

      Carbonaceous matter {TC = OC + EC} is often the largest contributor to PM2.5 mass. The Total Carbon Analyzer provides the result for TC.

      Since {TC = OC + EC}, it follows that {OC = TC EC}.

       

      The Magee Scientific Total Carbon Analyzer may be connected to a Model AE33 Aethalometer, which provides real-time data for BC, closely related to EC. The Aethalometer data is automatically combined with the TCA data to provide a full characterization of the carbonaceous component of the aerosol in near-real-time: TC, OC, BC (or EC).

      This is accomplished in a rugged, reliable instrument package that is suitable for laboratory, fieldwork, and routine Air Quality monitoring applications.

       

      RUGGED INSTRUMENT

      The Magee Scientific Total Carbon Analyzer Model TCA08 is constructed in a rugged instrument package suitable for laboratory, field-work and routine Air Quality monitoring applications.

       

      MEASUREMENT PRINCIPLE

      The Magee Scientific Total Carbon Analyzer collects a sample of atmospheric aerosols on a quartz fiber filter enclosed in a small stainless-steel chamber, at a controlled sampling flow rate of 16.7 LPM. The default sampling time is 60 minutes, but may be set from 20 minutes to 24 hours depending on the ambient aerosol concentrations.

      The instrument has two identical parallel channels, with the air flows being controlled by ball valves and solenoids. While one channel is collecting its sample, the other channel is analyzing the sample collected during the previous period. At the end of the period, the valves switch over to provide continuous operation and continuous data.

      After collection on the filter, two flash-heating elements combust the sample instantaneously in a small analyticflow of filtered ambient air. This converts all the carbonaceous compounds into CO2, and creates a short but large-amplitude pulse of CO2 in the analytic flow passed to the NDIR CO2 detector. The background level of CO2 in ambient air during the heating cycle is determined before and after the heating cycle, the provide the baselines against which the combustion pulse is measured. The CO2 concentration over the baseline is integrated to give the Total Carbon content of the sample.

      The chamber and combustion elements are cooled after analysis. At the end of the timebase period the flow system of ball valves and solenoids switches over. The first channel collects the next periods sample, while the second channel is analyzed.

       

       

      SPECIFICATIONS

      OPERATION

      Supply voltage: 100-240 V~, 50/60 Hz

      Max power consumption: 600 W (Heaters 400 W, Sample pump 100 W, Analytic flow pump 25 W)

      Airflow: Sample Airflow 16.7 LPM, Analytic Airflow 0.5 LPM

      Time resolution: 60 min (default); user-selectable 20 min to 24 hours

      ENVIRONMENTAL OPERATING CONDITIONS

      Indoor use, rack or benchtop (instrument)

      Altitude: up to 3000 m

      Temperature range: 10 40 degrees Celsius (instrument)

      Relative humidity range: non-condensing

      ANALYTICAL PERFORMANCE

      Sensitivity: 0.5 μg C/m3 at 60 min Sample time base and 16.7 LPM Sample Airflow

       

      MECHANICAL SPECIFICATION

      Chassis: standard 19’’/9U, rack mount, constructed of sheet metal

      Inlet plumbing requirement: the minimum overall height of the Total Carbon Analyzer (TCA) chassis and inlet tubing is 1.20 m. See Figure 1.

      Weight: 35 kg

       

      CONNECTORS

      Sampling air stream:

      l inlet: inner diameter 14 mm, outer diameter 18 mm, custom connectors. See Figure 2.

      outlet: .1/4NTPF

       

      Analytic air stream:

      l inlet: 1/8’’’ NTPF

      outlet: (internal, not brought to panel connector)

       

      Communications:

      l 6x COM, 4x USB 2.0, 1x USB 3.0, 3x power USB, Ethernet

       

      USER INTERFACE

      l 8.4SVGA display with LED backlight

      l Basic control: touch-screen

      l Optional control: standard PC keyboard and mouse

      l Red, Yellow, Green status LEDs

       

       

      深圳市現代豪方儀器儀表科技有限公司

      詢價請轉余工

    在線詢盤/留言
  • 0571-87774297  
    主站蜘蛛池模板: 亚洲а∨天堂久久精品| 动漫精品动漫一区三区3d| 337p日本欧洲亚洲大胆裸体艺术| 小帅男同志chinesecouple| 久久久久亚洲AV无码专区首| 欧美一区二区三区成人片在线| 亚洲线精品一区二区三区影音先锋| 精品国产电影久久九九| 国产亚洲人成a在线v网站| 麻豆国产一区二区在线观看| 国产色欲AV一区二区三区| acg里番全彩| 德国女人一级毛片免费 | 么公的又大又深又硬又爽视频| 欧美老人巨大xxxx做受视频 | 很黄很污的视频在线观看| 久久中文字幕2021精品| 日韩欧美亚洲乱码中文字幕| 亚洲中文字幕无码久久综合网| 欧美理论片在线| 亚洲精品第一国产综合精品| 男人桶爽女人30分钟视频动态图| 午夜三级限制福利电影在线看| 色多多视频在线| 国产中文字幕乱人伦在线观看| 韩国亚洲伊人久久综合影院| 国产成人一区二区精品非洲| 日本黄网站动漫视频免费| 国产精品无码无卡无需播放器| 97人人模人人爽人人少妇| 在线观看污污视频| av无码aV天天aV天天爽| 天天干在线观看| caopon国产在线视频| 天天爱天天做天天爽夜夜揉| а√天堂资源地址在线官网| 强行扒开双腿猛烈进入| 一级黄色片网站| 尤物国午夜精品福利网站| 一线高清视频在线观看www国产| 成人凹凸短视频在线观看|