      FEEDBACk VERSIOnS
      • Analog Sin/Cos
      • Quad A/B digital
      • Resolver
      COnTROL MODES
      • Indexer, Point-to-Point, PVT
      • Camming, Gearing, Position, Velocity, Torque
      COMMAnD InTERFACE
      • CAnopen
      • ASCII and discrete I/O
      • Stepper commands
      • ±10 Vdc position/velocity/torque command
      • PWM velocity/torque command
      • Master encoder (Gearing/Camming)
      • Digital inputs for indexer control
      COMMUnICATIOnS
      • CAnopen
      • RS232
      FEEDBACk
      • Digital Quad A/B encoder
      • Analog sin/cos encoder (-S versions)
      • Resolver (-R versions)
      • Secondary encoder / emulated encoder out
      • Digital Halls
      I/O - DIGITAL
      • 14 inputs, 4 outputs
      REGEn
      • Internal
      DIMEnSIOnS: MM [In]
      • 126 x 89 x 53 [5.0 x 3.5 x 2.1]

      Model Vac Ic Ip
      XSJ-230-02 100-240 1 2
      XSJ-230-06 100-240 3 6
      XSJ-230-10 100-240 5 10
      * Add “-S” to part number for Sin/Cos version
      Add “-R” to part number for Resolver versionDESCRIPTIOn
      Xenus Micro is a compact, AC powered servo drive for position,
      velocity, and torque control of AC brushless and DC brush motors.
      It operates on a distributed control network, as a stand-alone
      indexing drive, or with external motion controllers.
      Feedback options now include brushless resolvers in addition to
      digital quad A/B and analog sin/cos incremental encoders. The
      multi-mode encoder port operates as an input or output for the
      feedback signals. As an input, a secondary digital quad A/B encoder
      is used for dual-loop position control. Resolver and sin/cos signals
      are interpolated internally with programmable resolution and appear
      as digital quad A/B signals when the port functions as an output. Or,
      the digital quad A/B signals are simply buffered and made available
      to the system controller, eliminating cumbersome Y-cabling to share
      a single encoder with drive and control system.
      FEEDBACk VERSIOnS
      • Analog Sin/Cos
      • Quad A/B digital
      • Resolver
      COnTROL MODES
      • Indexer, Point-to-Point, PVT
      • Camming, Gearing, Position, Velocity, Torque
      COMMAnD InTERFACE
      • CAnopen
      • ASCII and discrete I/O
      • Stepper commands
      • ±10 Vdc position/velocity/torque command
      • PWM velocity/torque command
      • Master encoder (Gearing/Camming)
      • Digital inputs for indexer control
      COMMUnICATIOnS
      • CAnopen
      • RS232
      FEEDBACk
      • Digital Quad A/B encoder
      • Analog sin/cos encoder (-S versions)
      • Resolver (-R versions)
      • Secondary encoder / emulated encoder out
      • Digital Halls
      I/O - DIGITAL
      • 14 inputs, 4 outputs
      REGEn
      • Internal
      DIMEnSIOnS: MM [In]
      • 126 x 89 x 53 [5.0 x 3.5 x 2.1]
      Model Vac Ic Ip
      XSJ-230-02 100-240 1 2
      XSJ-230-06 100-240 3 6
      XSJ-230-10 100-240 5 10
      * Add “-S” to part number for Sin/Cos version
      Add “-R” to part number for Resolver version
      Indexing mode simplifies operation with PLC’s that use outputs to
      select and launch indexes and inputs to read back drive status. A
      single serial port on the PLC can send ASCII data to multiple drives
      to change motion profiles as machine requirements change.
      CAN bus operation supports Profile Position, Profile Velocity, Profile
      Torque, Interpolated Position, and Homing. Up to 127 Xenus Micro
      drives can operate on a single CAn bus and groups of drives can be
      linked via the CAN so that they execute motion profiles together.
      Operation in torque (current), velocity, and position modes with
      external motion controllers is supported. Input command signals
      are ±10 Vdc (torque, velocity, position),PWM/Polarity (torque,
      velocity), or Step/Direction (position).

      GEnERAL SPECIFICATIOnS
      Test conditions: Load = Wye connected load: 2 mH + 2 Ω line-line. Ambient temperature = 25°C, +HV = HVmax
      MODEL XSJ-230-02 XSJ-230-06 XSJ-230-10
      OUTPUT POWER
      Peak Current 2 (1.4) 6 (4.2) 10 (7.1) Adc (Arms, sinusoidal), ±5%
      Peak time 1 1 1 Sec
      Continuous current 1 (0.7) 3 (2.1) 5 (3.5) Adc (Arms, sinusoidal), ±5%
      InPUT POWER
      HVmin~HVmax 85 to 264 Vac 1 Ø, 50~60 Hz
      +24 Vdc +20 to +32 Vdc @ 500 mAdc maximum Logic & control power, required for operation
      PWM OUTPUTS
      Type 3-phase MOSFET inverter, 15 kHz center-weighted PWM, space-vector modulation
      PWM ripple frequency 30 kHz
      REGEnERATIOn
      Type Internal MOSFET dissipator
      Power dissipation 80 W peak, 40 W continuous
      Cut-In Voltage +HV > 390 Vdc Regen output is on, regen dissipator is dissipating energy
      Drop-Out Voltage +HV < 380 Vdc Regen output is off, regen dissipator not dissipating energy
      Tolerance ±2 Vdc For either Cut-In or Drop-Out voltage
      Hysteresis 10 ±0.5 Vdc Differential between Cut-In & Drop-Out voltage
      DIGITAL COnTROL
      Digital Control Loops Current, velocity, position. 100% digital loop control
      Dual loop position control using secondary encoder input
      Sampling rate (time) Current loop: 15 kHz (66.7 us) Velocity, position loops: 3 kHz (333 us)
      Commutation Sinusoidal field-oriented control or trapezoidal for brushless motors
      Bandwidth Current loop: 2.5 kHz typical, bandwidth will vary with tuning & load inductance
      HV Compensation Changes in bus voltage do not affect bandwidth
      Minimum load inductance 200 μH line-line
      COMMAnD InPUTS
      CAN CANopen: Profile Position, Interpolated Position, Profile Velocity, Profile Torque, Homing
      ASCII Single RS-232 connection passes messages to multiple drives via CAn link drive-drive
      Digital position reference Step/Direction or CW/CCW Stepper commands (1.5 MHz maximum rate)
      Quad A/B Encoder 20 Mcount/sec after quadrature (5 Mline/sec)
      Digital torque & velocity PWM/Polarity PWM = 0~100%, Polarity = 1/0
      PWM/50% PWM = 50% ±50%, no polarity signal required
      PWM frequency range 1 kHz minimum, 100 kHz maximum
      PWM minimum pulse width 220 ns
      Analog torque, velocity, position ±10 Vdc, 5 kΩ differential input impedance, 12-bit resolution
      Indexing Index address, index-start, priority-index start
      Camming Inputs for master encoder, cam start, cam table address
      DIGITAL InPUTS
      number 14: 12 programmable, 1 input dedicated to drive Enable function, 1 for motor temperature switch
      Type 8 General-purpose (GP), 3 high-speed single-ended (HS), 2 high-speed differential (HSD), 1 motemp (GP)
      GP, HS 74HC14 Schmitt trigger operating from 5.0 Vdc with RC filter on input,
      10 kΩ to +5 Vdc or ground (programmable), Vin-LO < 1.35 Vdc, Vin-HI >3.65 Vdc
      +10 Vdc max for HS inputs, +24 Vdc max for GP inputs
      1.5 MHz maximum pulse frequency for HS inputs when driven by active (not open-collector) sources
      HSD Differential, 121 Ω line-line, 100 ns RC filters to RS-422/RS-485 line receivers, +10 Vdc max
      5 MHz maximum pulse frequency when driven by differential line-drivers
      Pull-up, pull-down control GP & HS inputs are divided into three groups with selectable connection of input pull-up/down resistor
      to +5 Vdc or ground for each group: [In1,2,3,4], [In5,6,7,8], [In9,10,11]
      DIGITAL OUTPUTS
      number 4
      [OUT1], [OUT2], [OUT3] Current-sinking MOSFET with 1 kΩ pull-up to +5 Vdc through diode
      Ratings 250 mAdc max, +30 Vdc max
      External flyback diode required if driving inductive loads
      Brake [OUT4] Opto-isolated, current-sinking with flyback diode to +24 Vdc, 1 Adc max
      RS-232 PORT
      Mode Full-duplex, DTE serial communication port for drive setup and control; 9,600 to 115,200 baud,
      8 data bits, no parity, 1 stop-bit
      Signals RxD, TxD, Gnd
      Protocol Binary or ASCII formats
      Multi-Drop ASCII communications to multiple Copley drives via a single RS-232 port:
      RS-232 to first Drive_0, then daisy-chain to Drive_1~Drive_N via CANCAn PORT
      Format CAn V2.0b physical layer for high-speed connections compliant
      Data CANopen Device Profile DSP-402
      Signals CAnH, CAnL, Gnd
      Isolation CAn interface circuit and +5 Vdc supply are optically isolated from drive circuits
      Address selection Selectable by logic inputs or programmable in flash memory
      MOTOR COnnECTIOnS
      Power U-V-W phases for brushless, U-V for brush motors
      Commutation Digital Halls, or sin/cos feedback from ServoTube motors
      Feedback Digital quadrature A/B/(X) encoders; differential inputs (Standard)
      Analog sin/cos encoders, 1 Vpeak-peak, differential inputs with 121 Ω terminating resistor (-S option)
      Resolver, brushless, single-speed, 1:1 to 2:1 programmable transformation ratio (-R option)
      See page 4 for details on encoders and resolvers
      Brake Digital output, isolated, 1 Adc, +30 Vdc max, programmable, with flyback diode to +24 Vdc
      Overtemp sensor Digital input, non-isolated, 4.99 kΩ pull-up to +5 Vdc, programmable
      MULTI-MODE EnCODER PORT
      As Secondary Encoder Input Digital quadrature encoder (A, /A, B, /B, X, /X),
      20 M counts/sec, post-quadrature (5 M lines/sec)
      As Emulated Encoder Output Quadrature encoder emulation with programmable resolution to 4096 lines (65,536 counts) per rev
      from analog sin/cos encoders. 18 M counts/sec, post-quadrature (4.5 M lines/sec)
      As Buffered Encoder Output Buffered signals from digital quad A/B/X primary encoder. 20 M counts/sec, post-quadrature (5 M lines/sec)
      A, /A, B, /B, X, /X, signals from 26LS31 differential line driver
      LED InDICATORS
      Drive Status Bicolor LED, drive status indicated by color, and blinking or non-blinking condition
      CAn Status Bicolor LED, status of CAn bus indicated by color and blink codes to
      CAN Indicator Specification 303-3
      PROTECTIOnS
      HV Overvoltage +HV > 400 Vdc Drive PWM outputs disabled
      HV Undervoltage +HV < 60 Vdc Drive PWM outputs disabled
      Drive over temperature Heatplate > 70 °C ±3 °C Drive PWM outputs disabled
      Short circuits Output to output, output to ground, internal PWM bridge faults
      I2T Current limiting Programmable: Current foldback to continuous limit when I2T threshold is exceeded
      Motor over temperature Drive PWM outputs disabled when [In14] changes state (programmable)
      Feedback power loss Fault occurs if feedback +5 Vdc output is < 85% of nominal value
      MECHAnICAL & EnVIROnMEnTAL
      Size 126 x 89 x 53 [5.0 x 3.5 x 2.1] mm [in]
      Weight 0.67 lb (0.30 kg)
      Ambient Temperature Range 0 to +45 °C operating, -40 to +85 °C storage
      Humidity 0% to 95%, non-condensing
      Vibration 2 g peak, 10~500 Hz (sine), IEC60068-2-6
      Shock 10 g, 10 ms, half-sine pulse, IEC60068-2-27
      Contaminants Pollution degree 2
      Environment IEC68-2: 1990
      Cooling Heat sink and/or forced air cooling required for continuous power outputCAn PORT
      Format CAn V2.0b physical layer for high-speed connections compliant
      Data CANopen Device Profile DSP-402
      Signals CAnH, CAnL, Gnd
      Isolation CAn interface circuit and +5 Vdc supply are optically isolated from drive circuits
      Address selection Selectable by logic inputs or programmable in flash memory
      MOTOR COnnECTIOnS
      Power U-V-W phases for brushless, U-V for brush motors
      Commutation Digital Halls, or sin/cos feedback from ServoTube motors
      Feedback Digital quadrature A/B/(X) encoders; differential inputs (Standard)
      Analog sin/cos encoders, 1 Vpeak-peak, differential inputs with 121 Ω terminating resistor (-S option)
      Resolver, brushless, single-speed, 1:1 to 2:1 programmable transformation ratio (-R option)
      See page 4 for details on encoders and resolvers
      Brake Digital output, isolated, 1 Adc, +30 Vdc max, programmable, with flyback diode to +24 Vdc
      Overtemp sensor Digital input, non-isolated, 4.99 kΩ pull-up to +5 Vdc, programmable
      MULTI-MODE EnCODER PORT
      As Secondary Encoder Input Digital quadrature encoder (A, /A, B, /B, X, /X),
      20 M counts/sec, post-quadrature (5 M lines/sec)
      As Emulated Encoder Output Quadrature encoder emulation with programmable resolution to 4096 lines (65,536 counts) per rev
      from analog sin/cos encoders. 18 M counts/sec, post-quadrature (4.5 M lines/sec)
      As Buffered Encoder Output Buffered signals from digital quad A/B/X primary encoder. 20 M counts/sec, post-quadrature (5 M lines/sec)
      A, /A, B, /B, X, /X, signals from 26LS31 differential line driver
      LED InDICATORS
      Drive Status Bicolor LED, drive status indicated by color, and blinking or non-blinking condition
      CAn Status Bicolor LED, status of CAn bus indicated by color and blink codes to
      CAN Indicator Specification 303-3
      PROTECTIOnS
      HV Overvoltage +HV > 400 Vdc Drive PWM outputs disabled
      HV Undervoltage +HV < 60 Vdc Drive PWM outputs disabled
      Drive over temperature Heatplate > 70 °C ±3 °C Drive PWM outputs disabled
      Short circuits Output to output, output to ground, internal PWM bridge faults
      I2T Current limiting Programmable: Current foldback to continuous limit when I2T threshold is exceeded
      Motor over temperature Drive PWM outputs disabled when [In14] changes state (programmable)
      Feedback power loss Fault occurs if feedback +5 Vdc output is < 85% of nominal value
      MECHAnICAL & EnVIROnMEnTAL
      Size 126 x 89 x 53 [5.0 x 3.5 x 2.1] mm [in]
      Weight 0.67 lb (0.30 kg)
      Ambient Temperature Range 0 to +45 °C operating, -40 to +85 °C storage
      Humidity 0% to 95%, non-condensing
      Vibration 2 g peak, 10~500 Hz (sine), IEC60068-2-6
      Shock 10 g, 10 ms, half-sine pulse, IEC60068-2-27
      Contaminants Pollution degree 2
      Environment IEC68-2: 1990
      Cooling Heat sink and/or forced air cooling required for continuous power output
    在線詢盤/留言
  • 0571-87774297  
    主站蜘蛛池模板: 国产精品嫩草影院在线播放| 成在人线av无码免费高潮水 | 扒开内裤直接进| 久青草影院在线观看国产| 欧美精品v国产精品v| 免费成人av电影| 精品韩国亚洲av无码不卡区| 国产三级小视频在线观看| 黄频免费观看在线播放| 国产精品一区二区三区久久| 91欧美一区二区三区综合在线| 天堂资源wwww在线看| 一个人看的www在线观看免费| 成人性生交大片免费看| 久久一本岛在免费线观看2020| 日韩一级免费视频| 久久综合视频网| 最近中文字幕高清免费大全8| 亚洲国产欧美国产综合一区| 欧美疯狂性受xxxxx另类| 亚洲精品动漫免费二区| 猫咪免费人成网站地址| 免费精品久久天干天干| 美女被免费网在线观看网站| 国产一级毛片免| 蜜桃麻豆www久久国产精品| 国产免费拔擦拔擦8x高清在线人| 国产精品揄拍一区二区| 国产欧美曰韩一区二区三区| 69xx免费观看视频| 国产精品嫩草影院在线播放| 2020天堂中文字幕一区在线观| 国产美女久久久| 91亚洲精品视频| 国产裸体歌舞一区二区| 91精品国产免费入口| 国产青青在线视频| 77777亚洲午夜久久多喷| 国产网站麻豆精品视频| 7777精品久久久大香线蕉| 国产精品露脸国语对白|